It is used to test the performance of various products in heat resistance,cold resistance,dry resistance and humidity resistance. Mainly used in semiconductor chips,scientific research institutions, quality inspection,new energy,optoelectronic communications,aerospace military industry, automobile industry,LCD display,medical and other high-tech industries.
Testing standard:
1.B/T 2423.1 Low temperature test method
2.GJB 150.3 high temperature test
3.GB/T 2423.2 high temperature test method
4.GJB 150.4 low temperature test
5.GB/T2423.34 humid heat cycle test method
6.GJB 150.9 damp heat test
7.IEC60068-2 temperature and humidity test method
8.MIL-STD-202G-103B humidity test
1.Technical parameter: |
||||||||
Name |
Walk-in temperature and humidity chamber |
|||||||
Mold |
WBE-BRS-6m³-A/B/C/D/E |
WBE-BRS-8m³-A/B/C/D/E |
WBE-BRS-12m³-A/B/C/D/E |
WBE-BRS-24m³-A/B/C/D/E |
WBE-BRS-36m³-A/B/C/D/E |
WBE-BRS-60m³-A/B/C/D/E |
WBE-BRS-80m³-A/B/C/D/E |
WBE-BRS-120m³-A/B/C/D/E |
Volume(m³) |
6m³ |
8m³ |
12m³ |
24m³ |
36m³ |
60m³ |
80m³ |
120m³ |
Working room size (WxDxH)(cm) |
200x150x200 |
200x200x200 |
300x200x200 |
400x300x200 |
450x400x200 |
500x400x300 |
800x400x250 |
800x450x350 |
Customized possible |
||||||||
Window(WxH) |
360x510mm*2 |
|||||||
Voltage AC(V) |
AC380V±10%,50Hz±1Three-phase four-wire + ground cable (3/N/PE) with a ground resistance > 4Ω |
|||||||
Environmental requirement |
Air cooling ambient temperature requirements +5~ +30℃/ Water cooling ambient temperature requirements +5~ +40℃ (Water cooling requires a water tower or chiller) |
|||||||
Load |
Base on customer’s requirement |
|||||||
Temperature performance index: |
||||||||
Temperature range |
A:-40℃~+100℃,B:-20℃~+100℃,C:-50℃~+100℃,D:-70℃~+100℃,E:-60℃~+100℃, A1:-40℃~+150℃,B1:-20℃~+150℃,C1:-50℃~+150℃,D1:-70℃~+150℃,E1:-60℃~+150℃, Normal:A -40℃~+100℃。 |
|||||||
Temperature uniformity |
≤2.0℃ |
|||||||
Temperature deviation |
≤±2℃ |
|||||||
Temperature fluctuation |
≤±0.5℃ (≤±0.5℃,Base on GB/T5170-1996)。 |
|||||||
Heating rate |
Heating rate: average 1~2℃/min; (Temperature rate 2 ~ 25℃/ min linear/nonlinear for special conditions need to be customized)。 |
|||||||
Cooling rate |
Cooling rate: average 1℃/min; (Temperature rate 2 ~ 25℃/ min linear/nonlinear for special conditions need to be customized) |
|||||||
Humidity performance index: |
||||||||
Temperature range |
+10℃~+95℃。 |
|||||||
Humidity range |
20%RH~98%RH(10%~98%R.H;Customized for special conditions)。 |
|||||||
Humidity uniformity |
≤3.0%RH。 |
|||||||
Humidity deviation |
±3.0%RH(>75%RH),±5.0%RH(≤75%RH)。 |
|||||||
Humidity fluctuation |
≤±3.0%RH。(Non-load) |
|||||||
Temperature and humidity all test points |
For details, see 2.2 Temperature and Humidity Control Capability Diagram. |
|||||||
Time resolution of temperature and humidity |
Temperature:0.01℃;Humidity: 0.1%;Time: 0.01min。 |
|||||||
structure |
Field assembly type, the test box is composed of three parts: thermal insulation box + refrigeration unit cabinet + electrical control cabinet |