Products

Basket hanging temperature impact test chamber

Product description

Intro:

It is used to test the degree of endurance of various materials under the continuous environment of extremely high temperature and extremely low temperature in an instant, so as to detect chemical changes or physical damage caused by thermal expansion and contraction of samples in the shortest time. Mainly used in semiconductor chips, scientific research institutions, quality inspection, new energy, optoelectronic communications, aerospace military, automotive industry, LCD display, medical and other science and technology industries.

 

Other name:

Basket type high and low temperature (temperature) impact test chamber, Two-zone type cold and hot impact test chamber, Two-zone type high and low temperature impact test chamber, Two-zone type temperature impact test chamber, high and low temperature impact test chamber, temperature impact test chamber.

 

Meet test criteria:

Test method specification: GB/T2423.22; MIL STD 202F,method 107G; IEC 60068-2-14,Test Na; BS 2011;

DIN 40046,Test Na; JESD22-A101-A.

Product features
01
Adopt the most cutting-edge electronic expansion valve technology;
02
Energy saving about 30%;
03
Continuous impact 1000 times without defrosting (optional);
04
Evaporator is not easy to frost;
05
Linear model is more convenient to realize;
06
Stable and fast temperature, better uniformity control;
07
The compressor is not easy to frost, the whole machine life is longer than the traditional technology 1/3;
08
ESS box load heating automatic adaptation;
09
High temperature area and low temperature area, the test product is placed in the basket, and the basket switches in the high temperature area and low temperature area during impact
Technical specifications

Main technical parameters

Mode

WBE-LR2-49LA/B/C

WBE-LR2-100LA/B/C

WBE-LR2-150LA/B/C

WBE-LR2-250LA/B/C

WBE-LR2-450LA/B/C

WBE-LR2-1000LA/B/C

Volume(L)

49L

100L

150L

250L

450L

1000L

Basket size WxDxH(mm)

400×350×350

500×500×400

600×500×500

700×600×600

800×800×700

1000×1000×1000

Outer size WxDxH(mm)

1180x1850x1913

1280X1900X2215

1380x2000X2215

1480x2175X2215

1480x2376x2410

1780x2710X2876

Basket temperature range

150℃~ABC

150℃~ABC

150℃~ABC

150℃~ABC

150℃~ABC

150℃~ABC

A -40

B -55

C-65

A -40

B -55

C-65

A -40

B -55

C-65

A -40

B -55

C-65

A -40

B -55

C-65

A -40

B -55

C-65

Overall power KW

7.75

8.75

10.75

12.5

14

15.5

21.25

24.25

27.25

28

31

35.5

37.9

45.4

45.4

50

57.5

57.5

Tonnage of water tower RT

Air cooling is not required

5

Air cooling

5

8

8

10

12

10

12

15

15

20

20

20

25

25

Water discharge m³/h

/

/

2.35

/

3.9

4.68

6.24

7.8

9.36

7.8

9.36

11.7

11.7

15.6

15.6

15.6

19.5

19.5

Pipe diameter DN/mm

/

/

40

/

40

40

50

50

50

50

50

50

50

65

65

65

65

65

Window size W*H(mm)

W210*H300*2

W280*H350*2

W280*H350*2

W290*H420*2

W350*H500*2

W350*H500*2

Noise(dB)

≤72dB

≤72dB

≤72dB

≤75dB

≤75dB

≤75dB

Heat storage temperature time

RT~200℃ approximately take≤30min

Storage temperature time

A:+20~ -50℃ approximately take 35min      B:+20~ -65℃ approximately take ≤45min       C:+20~ -75℃ approximately take 55min

High temperature impact range

+60℃~ +150℃

Low temperature impact range

A:-10℃~ -40℃            B:-10℃~ -55℃             C:-10℃~ -65℃

Temperature fluctuation

≤±0.5℃

Temperature uniformity

≤2.0℃ non-load

Temperature deviation

≤±2.0℃ non-load

Basket conversion time

5S

Temperature recovery time

≤ 5min

High temperature exposure 15min/ low temperature exposure 15min

Continuous testing without defrosting times

1000 times (without defrosting) optional if required

Operating ambient temperature

Air cooling ambient temperature requirements 5~ +30℃/ Water cooling ambient temperature requirements +5~ +40℃ (water cooling requires a water tower or ice water machine)

 

Test product mobile type, preheating zone, precooling zone two zone structure

Weight (approx) (Kg)

1000

1200

1600

1900

2500

3500

Temperature-time resolution

Temperature:0.01℃;Time: 0.01min。

Standard fittings

insulated glass viewing window 1pcs, samples rack 2pcs, measuring hole diameter 50mm*1pcs, power cord, instruction manual.

Power suply

AC380V±10%,50Hz±1Three-phase four-wire + ground cable (3/N/PE), the ground resistance is < 4Ω